350 Cable Survey System
DPN 402197 © TSS (International) Ltd Page 4 of 10
Power-on the SDC:
Check that you have connected an AC electrical supply of the correct rating to the
three-pin IEC mains inlet on the SDC (refer to sub-section 4.2 for instructions to con-
nect power to the SDC).
Remove any disks that might be loaded into the drives. Operate the power switch to
power-on the SDC.
After you power-on the SDC, the ‘POWER’ LED should show green and the ‘HDD’
LED should flicker green as the SDC begins an initialisation sequence that lasts
approximately a minute. The SDC will launch Microsoft Windows and the DeepView
for Windows display software automatically after it has completed the initialisation
sequence.
Provided the software launches successfully, you will see the DeepView for Windows
opening splash screen. DeepView for Windows will then search for an initialisation file
on the SDC that includes details of the previous operating configuration. If the soft-
ware finds the initialisation file and the SDC receives data packets from the SEP that
are compatible with that file, then it will begin to operate using the same configuration.
Otherwise, DeepView for Windows will launch the System Configuration Wizard that
allows you to define the operating parameters used by the System.
To start the display software from Windows, select StartPROGRAMSDeepView for
WindowsDeepView for Windows.
The SDC is provided with a keyboard/trackpad combination. You may use a mouse or
the supplied trackpad to select commands and options from within DeepView for Win-
dows. You may use the keyboard to enter commands.
Under some circumstances, DeepView for Windows may not be able to communicate
with the SEP even though the ‘C/LOOP’ LED is showing red. This might occur, for
example, if the characteristics of the umbilical cable are unsuitable for use with 2-wire
current-loop communications. You may then have to reconfigure the 350 System to
use a different communication method – see sub-section 4.2.2. See also the fault
identification sequences described in sub-section 9.3.