7 – Operating Procedure
DPN 402197 © TSS (International) Ltd Page 11 of 30
Notes:
1. The Start character is a colon.
2. ‘F’ identifies a packet from the Forward search mode. The SDC transmits this type
of packet whenever it is displaying the Forward Search screen.
3. The Quality Control (QC) flag will be a space character when RESET, or a ques-
tion mark (?) when SET. See also the QC check code later in this packet.
4. The forward search range (FWD) is measured from the reference line of the coil
array (identified in Figure 3–2). There are several conditions that will cause the
field to contain question marks:
The target is out of range
The 350 System cannot compute an accurate position for the target
Coil saturation has occurred because the tone signal is too strong
5. Coil altitude (ALT) information comes from an altimeter if the System includes one.
Otherwise, the information in this field will be the fixed coil height if available. For-
ward search mode is available only if information is available concerning the
height of the coils above the seabed, and so this field will always contain informa-
tion.
6. The signal strengths, in microvolts, measured on channel 1 (starboard lateral –
SL), channel 2 (starboard vertical – SV), channel 3 (port lateral – PL), channel 4
(port vertical – PV), channel 5 (starboard fore-aft – SF) and channel 6 (port fore-
aft – PF).
Information included in the above signal strength fields may have a very large
dynamic range, extending from less than 1µV to more than 7 volts. To allow for
simple encoding of this range, the System displays and logs values using the sci-
entific notation explained on page 9.
7. The QC check code provides additional status information that explains any
occurrence of the QC flag being set. The check code consists of a two-digit
number with the meanings defined in Table 7–4.
Table 7–4: QC check code meaning – Forward search mode
QC Check
Code
Meaning
00 Target in range. SF and PF 50µV; LAT ±2m. Quality flag is RESET.
07 Saturation in one or more coils. Quality flag is SET.
08 Target in range. SF or PF <50µV. Quality flag is SET.
99 Target out of range. FWD = 9999. Quality flag is SET.