D10 Expert
™
Dual Discrete Outputs
8 P/N 64154 rev. F
Banner Engineering Corp. • Minneapolis, MN U.S.A.
www.bannerengineering.com • Tel: 763.544.3164
Figure 9. Single-Point Dark SET (Light
Operate shown)
Sensor positions
window thresholds
≈10%
from the
presented condition
Sensor positions
threshold between
taught conditions
Threshold position
adjusted by
Manual Adjust
Threshold position
adjusted by
Manual Adjust
Sensor positions
threshold between
taught conditions
Sensor positions
threshold slightly below
the presented condition
Sensor positions
threshold slightly above
the presented condition
Darkest
(no signal)
Darkest
(no signal)
Darkest
(no signal)
Most Light
(saturated
signal)
Most Light
(saturated
signal)
Darkest
(no signal)
Most Light
(saturated
signal)
Most Light
(saturated
signal)
Condition
Presented
Sensing window size
adjusted by
Manual Adjust
Output OFF Output OFF
Output OFF
Output ON
Output ON
Darkest Taught
Condition
Lightest Taught
Condition
Position
adjusted by
Manual Adjust
Output OFF
Output ON
Condition
Presented
Output OFF Output ON
Condition
Presented
Darkest
(no signal)
Most Light
(saturated
signal)
Output OFF Output ON
2nd Taught
Condition
1st Taught
Condition
Position
adjusted by
Manual Adjust
Push Button
0.04 seconds ≤ “Click” ≤ 0.8 seconds
Remote Line
0.04 seconds ≤ T ≤ 0.8 seconds
Result
Access
SET Mode
•Pressandhold
Static push button
> 2 seconds
•Single-pulse
remote line
•Displayflashes“1st”
•Arrowiconturnsred
•Displayflashes“2nd”
•Arrowiconturnsred
SET Output OFF Condition
•PresentOutput
OFF condition
•Five-click
Static push
button
•PresentOutput
OFF condition
•Five-pulseremoteline
Threshold Condition Accepted
•Displayflashes“sngl”then“dr” twice
•SensorreturnstoRUNmodewithnewsettings
•Arrowiconturnsgreen
Threshold Condition Unacceptable
•Displayflashes“fail”andreturnsto“1st”
•Arrowiconremainsred
•After60seconds,sensorreturnstoRUNmode
(Arrow icon turns green) without changing
settings
T T T T
T
T T
T T
T T T
T T
TT T
TT T T
T T
T T
T
T T
T T T T
T
T T
T T
T T T
T T
TT T
TT T T
T T
T T
T
T T
Push Button
Remote
Mode
Threshold Offset
(counts above
taught signal value)
Super High-Speed 30
High-Speed 22
High-Power 9
Super High-Power 6
Figure 10. Dark SET Threshold Offset
Single-Point Dark SET
•Setsathresholdslightlyabovethetaughtcondition(seegure9).
•Anyconditionlighterthanthethresholdconditioncausestheoutputtochangestate.
•T
hresholdpositionisadjustableusing“+”and“-”buttons(seeManualAdjust,page9)
•Recommendedforapplicationswhereonlyoneconditionisknown,forexampleastabledark
background with varying lighter targets.
A single sensing condition is presented, and the sensor positions a threshold slightly above
the taught condition. When a condition lighter than the threshold is sensed, the output either
turnsONorOFF,dependingontheLight/DarkOperatesetting(seeSensorSetup,page10.)
Dark SET and Light/Dark Operate Selection
DarkSETteachestheOutputOFFconditionandforcesthesensorintoLightOperate(LO)
mode. The sensor can be reconfigured to Dark Operate (DO) mode after the condition has
been taught (see Sensor Setup, page 10).