Banner D10 Series Manual do Utilizador Página 12

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 16
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 11
D10 Expert
Dual Discrete Outputs
12 P/N 64154 rev. F
Banner Engineering Corp. Minneapolis, MN U.S.A.
www.bannerengineering.com Tel: 763.544.3164
Self-Diagnostic Error Modes
In the unlikely event that the setup parameters are lost or become corrupt, the display will
continuouslyscroll:“USErPSFError.”Reteachthesensortorecover.Iftheproblempersists,
contact your Banner representative for further information.
Gate Input
The pink wire is configured as a gate input. When this wire is pulled low (i.e., to the sensor
ground; 0-0.5V dc), it inhibits the outputs from switching, while all other sensor functions
continue to be enabled. This feature is useful for controlling when the outputs are allowed to
change states. Gate input function response time is 1 millisecond.
Required Fiber-Optic Cable
Banner P-Series plastic fibers
Sensing Beam
Visible red, 680 nm, or
Visible green, 525 nm, depending on model
Supply Voltage and Current
12 to 24V dc (10% maximum ripple) at less than 65 mA, exclusive of load
Supply Protection Circuitry
Protected against reverse polarity and transient voltage
Output Configuration
2 NPN or 2 PNP, depending on model
Output Rating
150 mA maximum load
OFF-state leakage current: < 10 µA at 24V dc
ON-state saturation voltage: NPN < 1.5V at 150 mA load
PNP < 2.5V at 150 mA load
Output Protection Circuitry
Protected against false pulse on power-up and continuous short-circuit
Output Response Time
Programmable, 50 microseconds, 200 microseconds, 1 millisecond, 2.5 milliseconds
NOTE: < 1 second delay on power-up; outputs do not conduct during this time.
Adjustments
Push-button or remote programming of response time, OFF-delay, light/dark operate, and display
Indicators
Four-digitdigitaldisplayplusLEDindicatorsforactivechannel,push-buttonlockout,OFF-delayandlight/dark
operate selection; 2 yellow output indicators
Construction
BlackABS/polycarbonatealloy(UL94V-0rated)housing,clearpolycarbonatecover
Environmental Rating
NEMA 1, IEC IP50
Connections
PVC-jacketed 2 m or 9 m (6.5' or 30') 6-wire integral cable or integral 6-pin Pico-style quick-disconnect
Operating Conditions
Temperature: -20° to +55°C (-4° to +131°F)
Storage Temperature: -20° to +80°C (-4° to +175°F)
Max. Rel. Humidity: 90% @ 50°C (non-condensing)
Number of Devices,
Stacked
Ambient Temperature
Rating
Load
Specification
3 55°C 150 mA
7 50°C 50 mA
10 45°C 50 mA
Installation
35 mm DIN rail or included mounting bracket
Certifications
Specifications