D10 Expert
Dual Discrete Outputs
6 P/N 64154 rev. F
Banner Engineering Corp. Minneapolis, MN U.S.A.
www.bannerengineering.com Tel: 763.544.3164
Push Button
Remote
0.04 sec. T ≤ 0.8 sec.
Result
Access SET
Mode
•Pressandhold
Static (-) button
> 2 seconds.
•Displayflashes“1st
•Arrowiconturnsred
•Presentsensingcondition.
•Single-pulse
the remote line.
•Displayflashes“2nd
•Arrowiconturnsred
SET Sensing Condition
•Presentsensing
condition.
•Double-clickthe
Static button.
•Double-pulse
the remote line.
TEACH conditions acceptable:
•Displayflashes“sngl,”
then“pttwice
•SensorreturnstoRUN
mode with new settings.
•Arrowiconturnsgreen
TEACH conditions unacceptable:
•Displayflashes“failand
returnsto1st
•Arrowiconremainsred
•After60seconds,sensor
returns to RUN mode
(Arrow icon turns green)
without changing settings.
TT
T
TTTT
TTT
TT
T
TTTT
TTT
dynamic
static
dynamic
static
dynamic
static
dynamic
static
dynamic
static
Single-Point Window SET
•SetsasingleONconditionthatextends200countsaboveandbelowthetaughtcondition
(including ±100 counts hysteresis)
•Allotherconditions(lighterordarker)resultinOFFoutput
•
Sensingwindow(sensitivity)isadjustableusing“+”and“-”buttons(seeManualAdjust,
page 9)
Window SET is most useful when a product may not always appear in the same place, or
when other signals may appear. Window SET designates a sensing window, with the Output
ON condition inside the window, and the Output OFF conditions outside the window (see
Figure 6). The sensor accepts a single sensing condition, and adds switching thresholds and
hysteresis above and below that condition to create a sensing window. Output ON and OFF
conditionscanbereversedbychangingLight/DarkOperatestatusinSETUPmode.
Window SET and Manual Adjust
Using Manual Adjust with Window SET expands or contracts the size of the window.
Sensor positions
window thresholds
± 100 counts from the
presented condition
Darkest
(no signal)
Most Light
(saturated
signal)
Taught
Condition
200 counts
Hysteresis
100 counts
Hysteresis
100 counts
Output OFF Output OFFOutput ON
Sensing window size adjusted by
Manual Adjust
Figure 6. Single-Point Window SET and
Hysteresis (Light Operate shown)