U-GAGE
®
QT50U DC Specifications
Linearity (Analog Models)
+/- 0.2% of span from 200 to 8000 mm; +/- 0.1% of span from 500 to 8000 mm (1 mm minimum)
Resolution/Repeatability
1.0 mm
Hysteresis
5 mm
Output Response Time
Analog models: 100 to 2300 milliseconds
Dual-discrete models: 100 to 1600 milliseconds
Minimum Window Size
20 mm
Adjustments
Sensing window limits: TEACH-Mode programming of near and far window limits may be set using the push buttons or remotely
using TEACH input.
Indicators
Green Power ON LED: Indicates power is ON
Red Signal LED: Indicates target is within sensing range, and the condition of the received signal.
TEACH/Output indicator (bicolor Yellow/Red):
Yellow–Target is within taught limits Yellow OFF (Discrete)–Target is outside taught window limits
Red–Sensor is in TEACH mode Yellow Flashing (Analog)–Target is outside taught window limits
Remote TEACH
See data sheet
Construction
Transducer: Ceramic/Epoxy composite Housing: ABS/Polycarbonate
Membrane Switch: Polyester Lightpipes: Acrylic
Environmental Rating
Leakproof design is rated IEC IP67; NEMA 6P
Connections
2 m or 9 m shielded 5-conductor (with drain) PVC jacketed attached cable, or 5-pin Euro-style quick-disconnect or 5-pin Mini-style
quick-disconnect. QD cordsets are ordered separately. See page 312.
Operating Conditions
Temperature: -20° to +70° C Relative humidity: 100%
Vibration and
Mechanical Shock
All models meet Mil Std. 202F requirements. Method 201A (vibration: 10 to 60Hz max., double amplitude 0.06", maximum
acceleration 10G). Also meets IEC 947-5-2 requirements: 30G 11 milliseconds duration, half sine wave
Temperature Warmup Drift
Less than 0.8% of sensing distance upon power-up with Temperature Compensation enabled
Application Notes
• Objects passing inside the specied near limit (200 mm ) may produce a false response
• For best accuracy, allow 30 minute warm-up before programming or operating
Certifications
Hookup Diagrams
Analog Models: MI09 (p. 760) Discrete Models: MI10 (p. 760)
(cont’d)
More
on next
page
U-GAGE
®
QT50U Universal Voltage Specifications
Effective Beam
See Charts EBPC-1, EBPC-2 and EBPC-3 on page 313.
Supply Voltage
85 to 264V ac, 50/60 Hz / 24 to 250V dc (1.5 watts max., exclusive of load)
Ultrasonic Frequency
75 kHz burst, rep. rate 96 milliseconds.
Supply Protection Circuitry
Protected against transient over voltages. DC hookup is without regard to polarity.
Output Protection
Protected against short circuit conditions
Delay at Power-up
1.5 seconds
Output Configuration
SPDT (Single-Pole, Double-Throw) electromechanical relay output.
One normally open (NO) and one normally closed (NC).
Output Ratings
Max. switching power (resistive load): 2000 VA, 240 W (1000 VA, 120 W for sensors with Micro QD)
Max. switching voltage (resistive load): 250V ac, 125V dc
Max. switching current (resistive load): 8A @ 250V ac, 8A @ 30V dc derated to 200 mA @ 125V dc
(4A max. for sensors with Micro QD)
Min. voltage and current: 5V dc, 10 mA
Mechanical life of relay: 50,000,000 operations
Electrical life of relay at full resistive load: 100,000 operations
NOTE: Transient suppression is recommended when switching inductive loads.
Temperature Effect
Uncompensated: 0.2% of distance/° C Compensated: 0.02% of distance/° C
Repeatability
1.0 mm
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com