SENSORS
More information online at bannerengineering.com302
LIGHT GAUGING ULTRASONIC MEASURING ARRAYS RADAR
Class 2 (Visible Alignment Laser)
Lasers that emit visible radiation in the wavelength
range from 400 to 700 nm where eye protection is
normally afforded by aversion responses, including the
blink reex. This reaction may be expected to provide
adequate protection under reasonably foreseeable
conditions of operation, including the use of optical
instruments for intrabeam viewing. Reference 60825-1
Amend. 2 © IEC:2001(E), section 8.2.
Class 1 (Infrared Sensing Laser)
Lasers that are safe under reasonably foreseeable
conditions of operation, including the use of optical
instruments for intrabeam viewing. Reference
60825-1 Amend. 2 © IEC:2001(E), section 8.2.
Operating Mode
Laser Class 1
Setup Mode
Laser Class 2
Do not stare into beam
L-GAGE
®
LT7 Specifications
Minimum Analog
Window Size
LT7PLVQ: Not Applicable
LT7PIDQ: 300 mm
Adjustments
Push-button-directed password enable/disable, measurement unit select, offset value select, output limits set, output mode select,
analog output slope select (diffuse models only) and output limit manual adjust. See data sheet for information.
Serial Interface
RS-422 or SSI compatible
Serial Measurement Speed
SSI: 1.4 milliseconds (SSI cycle 80 microseconds) RS-422: 2.9 milliseconds
@
57.6 kBaud
Indicators
4 LEDs:
Green: Power ON/OFF
Red: Alarm (Error) LED
Orange: Output 1 and Output 2 conducting LEDs
2-line digital LCD display. See data sheet for detailed information.
Construction
ABS shock-resistant housing; PMMA window; polycarbonate displays
Weight
Approximately 230 g
Environmental Rating
IEC IP67
Connections
12-pin M16 connector; 100 m max. cable length; use only cables listed on page 302.
Operating Conditions
Temperature: -10° to +50° C in continuous operation
Storage Temperature
-30° to +75° C
Vibration/Shock
EN 60947-5-2
Application Notes
All specifications are based on the specified surface at constant ambient conditions and following a minimum operating time of 15 minutes.
For best accuracy, allow a 15-minute warmup before programming or operating
Crosstalk avoidance: Light spots must be separated by at least 200 mm.
Certifications
Hookup Diagrams
MI05 (p. 759)
(cont’d)
Brackets
LT7
SMBLT7
pg. 658
M16 QD
See page 697
Length
Threaded 12-Pin
Straight Right-Angle
3 m MQDC-1210ST MQDC-1210RA
10 m MQDC-1230ST MQDC-1230RA
30 m MQDC-1290RA
Cordsets
REFLECTORS
PAGE 710
REFLECTORS
Additional cordset information available.
See page 679.
Additional brackets and information available.
See page 620.
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Vista de página 10
1 2 ... 6 7 8 9 10 11 12 13 14 15 16 ... 65 66

Comentários a estes Manuais

Sem comentários