R55 Expert Color Mark Sensors
P/N 59574 rev. B 9
Banner Engineering Corp. • Minneapolis, MN U.S.A.
www.bannerengineering.com • Tel: 763.544.3164
Specifications
Supply Input 10 to 30V dc (10% maximum ripple) at less than 80 mA, exclusive of load.
Supply Protection Circuitry Protected against reverse polarity and transient voltages.
Output Configuration Digital outputs: Bipolar. One current sourcing (PNP) and one current sinking (NPN) open-collector transistor
Analog output: Current source proportional to the received light level, updated in real time (every 50 microseconds)
Output Rating Digital outputs are 100 mA maximum (each)
Off-state leakage current < 10 microamps at 30V dc
Saturation voltage (NPN output) < 1.5V at 150 mA dc
Saturation voltage (PNP output) < 2.0V at 150 mA dc
Current Sourcing Analog output: 0 to 10 mA
Maximum load voltage drop is 2 volts
Output Protection Protected against false pulse on power-up and continuous overload or short-circuit of outputs.
Output Response 50 microseconds NOTE: 1 second delay on power-up; outputs do not conduct during this time.
Adjustments
(see pages 3–7)
Using push buttons (“+” Dynamic and “-” Static):
Manually adjust discrete output switchpoint using “+or “-” buttons
Dynamic TEACH (teach on-the-fly) sensitivity adjustment
Static TEACH sensitivity adjustment
Light operate/Dark operate
OFF-delay select: 0 milliseconds, 20 milliseconds or 40 milliseconds
Using Remote TEACH input (gray wire):
Dynamic TEACH (teach on-the-fly) sensitivity adjustment
Static TEACH sensitivity adjustment
Light operate/Dark operate
OFF-delay select: 0 milliseconds, 20 milliseconds or 40 milliseconds
Lockout of push buttons for security
Indicator LEDs 10-segment (green) light bar indicates signal strength
Light Operate: green
Dark Operate: green
Outputs Conducting: yellow
OFF-Delay (green): SETUP Mode RUN Mode
OFF no delay OFF no delay
Flashing 20 ms delay ON 20 or 40 ms Delay
ON 40 ms delay
Construction Zinc alloy die-cast and steel housing with black acrylic polyurethane finish
Lens and lens port cap are o-ring sealed
Lens is acrylic
Lens port cap and lens holder are ABS
Environmental Rating IEC IP67; NEMA 6
Connections PVC-jacketed 6-conductor 2 m (6.5') or 9 m (30') attached cable with internal strain relief, or 6-pin Euro-style
quick-disconnect. Mating QD cables are purchased separately. See Cables, page 10.
Operating Conditions Temperature: -1to +55° C (+14° to 131° F)
Maximum Relative Humidity: 90% at 50° C (non-condensing)
Vibration and
Mechanical Shock
All models meet IEC 68-2-6 and IEC 68-2-27 testing criteria.
Application Notes Do not mount the sensor directly perpendicular to shiny surfaces; position it at approximately a 15° angle in
relation to the sensing target (see page 8).
Minimize web or productflutter” whenever possible to maximize sensing reliability.
The analog output is proportional to the received light signal. The analog output is unaffected by + or
manual sensitivity adjustments.