E-Series 2-Color Models
Job light is Green at all times while job input is active
Presence of hand (or pressing push button) activates output
Presence of hand (or pressing push button) while job input is inactive causes unit to light Red, providing visual verification that sensor
is functioning properly
Model
Sensing Mode /
LED*
Housing Range Cable* Output*** Job Light
K50APLPGREQ
Polarized retroreflec-
tive, visible red, 680
nm
50 mm dome
30 mm mount
polycarbonate
2 m (6 ft)
Integral 4-
pin Euro QD
PNP, N.O.
Green (Red)
K50RPLPGREQ PNP, N.C.
K50ANLPGREQ NPN, N.O.
K50RNLPGREQ NPN, N.C.
K50APFF50GREQ
Fixed field infrared,
880 nm
50 mm cut-
off
PNP, N.O.
K50RPFF50GREQ PNP, N.C.
K50ANFF50GREQ NPN, N.O.
K50RNFF50GREQ NPN, N.C.
K50APFF100GREQ
100 mm cut-
off
PNP, N.O.
K50RPFF100GREQ PNP, N.C.
K50ANFF100GREQ NPN, N.O.
K50RNFF100GREQ NPN, N.C.
K50APPBGREQ
Push button
PNP, N.O.
K50RPPBGREQ PNP, N.C.
K50ANPBGREQ NPN, N.O.
K50RNPBGREQ NPN, N.C.
K80APPBGREQ
50 mm dome
Flat or DIN-
mount
polycarbonate
PNP, N.O.
K80RPPBGREQ PNP, N.C.
K80ANPBGREQ NPN, N.O.
K80RNPBGREQ NPN, N.C.
* Only 4-pin integral Euro-style QD models are listed. For 2 m (6 ft) PVC cable model, omit suffix “Q” from model number (e.g.,
K50RPLPGRE”). For 9 m (30 ft) PVC cable model, replace suffix “Q” with “W/30” (e.g., “K50RPLPGRE W/30”). For 150 mm (5.9 in)
PVC pigtail with 4-pin Euro-style fitting, replace suffix “Q” with “QP” (e.g., “K50RPLPGREQP”).
A model with a QD requires a mating cable (see 4-pin Euro-Style Cordsets).
**N.O. = Normally Open; N.C. = Normally Closed
WARNING: Not To Be Used for Personnel Protection
Never use this product as a sensing device for personnel protection. Doing so could lead to seri-
ous injury or death. This product does NOT include the self-checking redundant circuitry necessary to
allow its use in personnel safety applications. A sensor failure or malfunction can cause either an ener-
gized or de-energized sensor output condition.
EZ-LIGHT® K50 and K80 Series Pick-to-Light Sensors