Banner PresencePLUS P4 EDGE 1.3 Series Manual do Utilizador Página 233

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 232
2. Use the scroll bar and select an Inspection Number by clicking in the dialog next to the number
where you want to store the inspection, or enter a number in the Inspection Number field.
3. In the Inspection Name field, enter a name for the inspection.
4. Click the Save button in the dialog.
Note: Check the Space Needed and Space Available fields to ensure there is room to save
an inspection. You can choose whether to save a reference image. Not saving a reference image
with the inspection frees up a lot of room onboard the sensor. However, inspections that include
any of the following tools require a reference image to be saved:
Geometric Find
Geometric Count
Pattern Find
Pattern Count
Color Match
Color BLOB
233Banner Engineering Corp. - Minneapolis, MN USA - www.bannerengineering.com
Tel: 763.544.3164
P/N 000000
Saving Inspections7/2009
Vista de página 232
1 2 ... 228 229 230 231 232 233 234 235 236 237 238 ... 257 258

Comentários a estes Manuais

Sem comentários